| Page | 01 |
|---|
| Article | Description / Summary |
|---|---|
| HLP1072 | How Can I? With The USC701 The attached document represents part of the USC701 training course. Following are some links to HTML articles that cover the same material. HOW DO I KNOW WHAT VALUES ARE IN EACH MEMORY ? CAN I STORE MORE THAN 10 NUMBERS? HOW MANY EQUATIONS ... |
| UAP0010 | Reverse Acting Relay with Long Off Delay Example Because the on and off delays on the relays only go up to 2330 seconds this example uses an equation to obtain a one hour delay. Operating Description If input on CH1 is below a low limit then RY1 should switch on. If input on CH1 then goes ... |
| HLP1068 | USC Calculation Speed Equation Calculation Time Command Time Floating point Addition 2ms Floating point Subtraction 2ms Floating point Multiplication 5ms Floating point Subtraction 5mS Integer Addition < 0.1ms Integer Subtraction < 0.1ms Integer Multiplication ... |
| HLP1069 | USC Measurement Speed CH1 and CH2 Measurement Rates For one channel of measurement , there is an overhead of one cycle of the sample rate after each sample time. For a 50Hz system, slow overhead is 20msec, fast overhead is approximately 1msec. Sample Time Setting ... |
| UAP1062 | USC701 Add Extra Relay This application illustrates the use of using the transistor output as a third relay. Two connection diagrams are provided; The 24V relay version will work provided the power supply is between 8 and 45Vdc and the relay coil voltage is the same ... |
| HLP1086 | USC701 Program Branching The USC701 can run different program instructions based on the value in the stack, the state of the relays, the state of the pulse inputs and keys on the AM702 ( hotkeys ). The program example shown ( UAP1096 ) uses branching to select either ... |
| HLP1085 | Use Tables in USC Equation Editor The USC701 has four look up tables to linearize measurements taken typically from industrial sensors. An example of this is the thermocouple . The USC configuration wizard creates hidden equations to directly linearize the sensor input. However ... |
| HLP1066 | View USC701 Memories While Running The Need to Display Input Values Displaying Input Values Limitations In Displaying Values Overcoming Limitations The Need to Display Input Values When trying to determine a problem or optimise any USC701 application you will generally want ... |
| HLP1067 | Why Is The USC701 Universal? Attached is a power point presentation, whyusc.ppt (390kb) . This article is an outline of that presentation with some links to knoledge articles that may be useful when preparing to use the PP presentation or as an outline to the USC701. Slide ... |
| HLP1090 | www- Guaranteed Method to get USC Application (UAP) Problem When I Click on the uapxxxxx.usc link instead of the application loading into USC Config I get comma delimited text in the browser window. Right click on the uapxxxxx.usc that you wish to use. Select "Save Target As... or "Save ... |