| Page | 01 | 02 | 03 |
|---|
| Article | Description / Summary |
|---|---|
| HLP0014 | USC Config - l. Import Export Data When the USC Config xxx program is installed its default location is C:\Program Files\APCS\USC Config 1 xx \ where xx is the sub version number of the internal USC software that the program is written for. Files installed in the program directory ... |
| HLP0015 | USC Config - m. Equation Editor Equation outputs are saved in memory location M4 to M9 or Mem4 to Mem9. The "modify wizard" is then used to connect M4 to M9 to the relays, analogue or pulse output. The equation can also directly manipulate the state of the ... |
| HLP1037 | USC Config - n. Create Simple Adder Using Wizard Run the New Module Wizard and select dc Signal, Adder then Next. Select channel 1 as 10Vdc then Next. Select channel 2 as 10Vdc then Next. Select the 0..22mA output on the range list. Select m4 0..20 Adder ([m4] [Min]..[Max] [Engineering Unit]) ... |
| HLP1038 | USC Config - o. Create Simple Divider using Wizard Run the New Module Wizard and select dc Signal, Divider then Next. Select channel 1 as 10Vdc then Next. Select channel 2 as 10Vdc then Next. The new module wizard added a simple equation (read CH1, read CH2, divide, save (Mem4) to the settings ... |
| HLP1039 | USC Config - p. Review Adder Wizard Equation Create a module definition file using the instructions in Create a Simple Adder using the New Module Wizard Select the Equation command button in the USC Properties screen then click the Configure button; the Special Function Equation Editor ... |
| HLP1040 | USC Config - q. Adder with Peak Output and Reset This exercise will take the previous input adder example and adda a peak measurement output that is reset to a minimum output level when a digital input is active. Create some program documentation. Enter the equation screen and click on the ... |
| HLP0016 | USC Config - r. Interface with Access Module Compatibility With The AM702 , Configurable User Interface This manual applies to: AM702-02 Plug on configuration module "USC Config 106" PC based configuration software Compatibility With The AM702 Any USC701 module programmed with ... |
| HLP1041 | USC Config - s. Create a Divider with Trim The first step is to create the USC program. Follow previous example " Create a Simple Divider using the New Module Wizard " When the error message occurs due to the divide by zero follow option " b. Enter Expected ... |
| HLP1042 | USC Config - t. Add Hot Keys to Control Branching Sample Program The AM702 will display: CH1 when keys are pressed. CH2 when keys are pressed. M4 when keys are pressed. This example follows the previous example " Create a Divider with Trim " however ... |
| HLP1043 | USC Config - u. Using Integer Maths Also see " The Equation Editor " The USC701 has four memories CH1, CH2, P1 and P2 (M0 to M3) that contain input measurements, these measurements are floating point numbers. The output devices O1 (mA, V, PWM, Frequency), RLY1 ... |